Part Number Ratio Voltage Ratio Price Lead Time
460-069-110 0.63:1 69:110 $486.31 7–9 weeks
460-069-120 0.58:1 69:120 $421.08 7–9 weeks
460-120-110 1.09:1 120:110 $486.31 7–9 weeks
460-120-120 1:1 120:120 $421.08 7–9 weeks
460-208-110 1.89:1 208:110 $486.31 7–9 weeks
460-208-120 1.73:1 208:120 $421.08 7–9 weeks
460-208-208 1:1 208:208 $421.08 7–9 weeks
460-220-120 1.83:1 220:120 $421.08 7–9 weeks
460-240-110 2.18:1 240:110 $486.31 7–9 weeks
460-240-120 2:1 240:120 $421.08 7–9 weeks
460-240-240 1:1 240:240 $421.08 7–9 weeks
460-277-110 2.52:1 277:110 $486.31 7–9 weeks
460-277-120 2.31:1 277:120 $421.08 7–9 weeks
460-280-120 2.33:1 280:120 $421.08 7–9 weeks
460-288-110 2.62:1 288:110 $486.31 7–9 weeks
460-288-120 2.4:1 288:120 $421.08 7–9 weeks
460-300-110 2.73:1 300:110 $509.10 7–9 weeks
460-300-120 2.5:1 300:120 $443.86 7–9 weeks
460-346-110 3.15:1 346:110 $509.10 7–9 weeks
460-346-120 2.88:1 346:120 $443.86 7–9 weeks
460-346-346 1:1 346:346 $443.86 7–9 weeks
460-360-120 3:1 360:120 $459.70 7–9 weeks
460-380-120 3.16:1 380:120 $459.70 7–9 weeks
460-400-120 3.33:1 400:120 $459.70 7–9 weeks
460-415-120 3.45:1 415:120 $459.70 7–9 weeks
460-440-110 4:1 440:110 $524.94 7–9 weeks
460-440-120 3.66:1 440:120 $459.70 7–9 weeks
460-480-110 4.36:1 480:110 $509.10 7–9 weeks
460-480-120 4:1 480:120 $443.86 7–9 weeks
460-480-150 3.2:1 480:150 $601.11 7–9 weeks
460-480-240 2:1 480:240 $596.75 7–9 weeks
460-480-480 1:1 480:480 $485.64 7–9 weeks
460-600-110 5.45:1 600:110 $508.85 7–9 weeks
460-600-120 5:1 600:120 $443.61 7–9 weeks
460-600-600 1:1 600:600 $546.60 7–9 weeks
460-690-110 6.27:1 690:110 $508.85 7–9 weeks
460-690-120 5.75:1 690:120 $443.61 7–9 weeks
460-720-120 6:1 720:120 $443.61 7–9 weeks

Potential Transformer Model 460

Potential Transformers are encased in a thermoplastic case with the core and windings encapsulated in resin. Designed for line to line operation but may also be used in a line to neutral or line to ground configuration at 58% of rated voltage. All transformers with rated voltages 346V and below are ANSI C57.13 Group 1. All transformers rated 480V and 600V are Group 2.

Frequency50/60 Hz
Secondary Voltage120 VAC or 240 VAC
Insulation Level600V, 10kV BIL Full Wave
Accuracy Class0.6W, 1.2X @ 60Hz / 0.5 @ 10VA, 1.0 @ 20VA @ 50Hz
Thermal Rating (60Hz)150 VA @ 30°C, 100 VA @ 55°C
Thermal Rating (50Hz)125 VA @ 30°C
StandardsANSI C57.13
  • Terminals are No. 10-32 brass studs with flat washer, lock washer and nut.
  • Recommend using a 1.6 Amp fuse in the 120V secondary to protect the transformer.
  • Recommend using a 0.75 Amp fuse in the 240V secondary to protect the transformer.
  • 480V and 600V rated units are ANSI C57.13 Group 2; all others are Group 1.